ORTHOPHOSPHATE PO4-P

Alyza IQ PO4

Orthophosphat analyzer for the IQ SENSOR NET

The perfect solution to support phosphate elimination as well as phosphate load monitoring – on-site analyzer for orthophosphate measurement in the IQ SENSOR NET:

  • Minimized reagent consumption and waste
  • Simple Service-Regular maintenance takes only 10 minutes every 3 months
  • Reliable results from low to high measuring levels
  • Compatible with IQ SENSOR NET

The Alyza IQ PO4 orthophosphate analyzer is another component for the IQ SENSOR NET. It can be easily integrated into new and existing systems just as simple as a sensor. The measuring principle is based on the photometric yellow method (molybdate vanadate), which has been a proven detection method for orthophosphate. Thanks to the wet chemical measurement directly in the process, Alyza IQ is the perfect solution to support phosphate elimination as well as monitoring the phosphate load.

Highlights:

  • Minimized reagent consumption and waste
    Alyza IQ boasts an extremely low use of reagents – an advantage that significantly reduces operating costs and waste generation
  • Simple Service
    Regular maintenance takes only 10 minutes every 3 months.
  • Reliable results from low to high measuring levelsThanks to the new technology, Alyza IQ provides an accurate and reliable measurement over the whole range of 0.02-15.00 mg/l and 0.2-50.0 mg/l PO4-P.
  • Automatic cleaning and calibration with standards
    The fully automated cleaning as well as 1- or 2-point calibration with selectable intervals ensures an exceptional degree of operational safety.
  • On-site installation
    Alyza IQ PO4 can be installed directly at the basin. This guarantees short transport distances and promptly measured values. Thanks to the climate package, the analyzer is perfectly suited for all weathers.
Measurement methodMolybdate-Vanadate method (Yellow method)
Measurement rangeOne measuring range
MR1:0.02 … 15.00 mg/l PO4-P
Displayed:0.00 … 15.00 mg/l PO4-P
Resolution:0.01 mg/l PO4-P
Accuracy:±2 % ±0.02 mg/l
MR2:0.2 … 50.0 mg/l PO4-P
Displayed:0.0 … 50.0 mg/l PO4-P
Resolution:0.05 mg/l PO4-P
Accuracy:±2 % ±0.2 mg/l
Sample streams/channels1- and 2-channel versions available
CleaningAutomatic cleaning with cleaning solutions
CalibrationAutomatic 1- and 2-point calibrations
Operational temperature-4 … 104 °F (-20 … +40) °C

*More instruments are available, please liaise with us if any of your required instruments is not listed above.