UV NOX AND SAC

UV NOx-N
UV 70x IQ NOx

Nox sensor for the IQ SENSOR NET UV 700 IQ NOx: Low-cost probe with integrated ultrasonic cleaning for the maintenance-free and reagent-free measurement of nitrate:

  • No replacement of seals or wiper profiles
  • Minimal effort thanks to maintenance-free WTW ultrasonic cleaning
  • No danger of emerging water thanks to completely sealed housing
  • No corrosion thanks to titanium housing
 

With the new sensor UV 700 IQ NOx, nitrate is detected via a UV absorption measurement at a wavelength below 250 nm. Turbidity influences are effectively compensated by a reference measurement. This cost-effective probe is especially suited to regulate or control intermittent aeration. Another field of application is the detection of nitrate in rivers.

ModelUV 701 IQ NOxUV 705 IQ NOx
Order No.481034481035
Measuring methodUV Single Wavelengths Absorption Measurement
Measuring gap (optical layer thickness)1 mm5 mm
Application (optimized for)Municipal wastewater with a low proportion of industrial wastewater, waste water treatment plants, surface water
Measuring range and ResolutionNOx0.0 … 500.0 mg/l 0.1 mg/l0.0 … 100.0 mg/l 0.1 mg/l
NOx-N0.0 … 100.0 mg/l 0.1 mg/l0.0 … 20.0 mg/l 0.1 mg/l
Flow rate≤ 3 m/s
Pressure ResistanceMaximum 1 bar (incl. sensor connection cable)
Electrical connections2-wire shield cable with quick fastener to sensor
Electromagnetic
Compatibility
EN 61326, Class B, FCC Class A
Intended for indispensable operation
CertificationsCE
MechanicalHousing: Titan Grade 2, PEEK; Window: Sapphire glass
Protection class: IP 68
Weight (without cable)Approx. 8.82 lb (4 kg)
Warranty2 years for defects in quality
SAC and UVT
UV 70x IQ SAC

SAC and UVT sensor for the IQ SENSOR NET UV 700 IQ SAC: Low-cost probe (integrated ultrasonic cleaning, turbidity compensation) for the maintenance-free and reagent-free SAC measurement according to DIN 38404 C3:

  • No wear parts
  • No replacement of seals
  • No risk of penetrating water
  • No corrosion With the new sensor UV 700 IQ SAC, you can determine the spectral absorption coefficient at 254 nm directly and without chemicals. Turbidity influences are compensated by a reference measurement at 550 nm.

As a sum parameter, similar to the COD, the SAC allows information about the organic contamination of water. This makes this sensor ideal to capture organic deposits in wastewater and surface waters. In addition to the SAC, you can use this sensor to determine the UV transmission at 254 nm. This is most commonly used in the control of UV disinfection systems.

DOC0.0 … 12,500 mg/l 1 mg/l0.0 … 500.0 mg/l 0.1 mg/lBOD0.0 … 8,000 mg/l 1 mg/l0.0 … 500.0 mg/l 0.1 mg/lSAC254 total0.0 … 3,000 1/m 1 1/m0.0 … 600.0 1/m 0.1 1/mSAC254 dissolv0.0 … 3,000 1/m 1 1/m0.0 … 600.0 1/m 0.1 1/mUVT254 total*0.0 … 100.0 % 0.1 %0.0 … 100.0 % 0.1 %UVT254 dissolv*0.0 … 100.0 % 0.1 %0.0 … 100.0 % 0.1 %

ModelUV 701 IQ SACUV 705 IQ SAC
Order No.481036481038
Measuring methodUV-Absorptionsmessung 254 nm (Kompensation 550 nm)
Measuring gap (optical layer thickness)1 mm5 mm
Application (optimized for)Municipal wastewater with a low proportion of industrial wastewater, wastewater treatment plants, surface water
Measuring range and ResolutionCOD0.0 … 12,500 mg/l 1 mg/l0.0 … 800 mg/l 1 mg/l
TOC0.0 … 20,000 mg/l 1 mg/l0.0 … 500.0 mg/l 0.1 mg/l
Flow rate≤ 3 m/s
Pressure ResistanceMaximum 1 bar (incl. sensor connection cable)
Electrical connections2-wire shield cable with quick fastener to sensor
Electromagnetic
Compatibility
EN 61326, Class B, FCC Class A
Intended for indispensable operation
CertificationsCE
MechanicalHousing: Titan Grade 2, PEEK; Window: Sapphire glass
Protection class: IP 68
Weight (without cable)Approx. 8.82 lb (4 kg)
Warranty2 years for defects in quality
* The UVT-254 value is standardized to 10 mm gap width.